ACRYLIC ROTAMETER
Acrylic Body Rotameter is basically a variable area flowmeter. It is used to measure the instant flow rate of liquid & gases. The essential working part is tapered flow tube precision machined inside the transparent acrylic block. When flow occurs. Position of float indicates the flow rate on scale engraved on acrylic body.
Technical Specifications
Fluid | : | Liquid & Gases |
Density / Sp. gravity | : | Up to 1.85 |
Viscosity | : | Up to 100 cp |
Design Temperature | : | Up to 40:0 |
Design Pressure | : | Up to 6 Kg/cm2 |
Measuring range | : | 2.5 to 15,000 LPH of Water / Liquid 0.1 to 525 Nm3/hr of Air/ Gas NTP |
Line Size | : | Up to 1" to 3" NB |
End Connection Materials | : | SS304 / SS304L / SS316 / SS316L PTFF / PVC /PP |
Connection | : | Flanged to ASA/BS/DIN Triclover Screwed to BSP/NPT(M/F) |
Design & Calibration Confirms to ISA-PR16.5 & ISA-PR16.6
Send QueriesBASKET TYPE STRAINER
A device through which a iiquid IS passed for purification, tutoring or soparation from solid manor; anything (including a screen or a cloth) used to strain a liquid They are most commonly used In pressurized lines, gas or liquid, but can also be used in suction or vacuum conditions. V-Strainer has the advantage of being able to too installod in oithor a horizontal Or vortical position.
Send QueriesBYPASS ROTAMETER
By Pass Rotameter Suitable for high range of fluid in pipe line between 2'" or above upto 300 mm NB. Where on line rotameter cant be used. It consist of one orifice plate to be mounted in the pipe line between two flange. one more integral orifice with two inlet & outlet & one by pass Rotameter is provided to read, direct flow.
DOUBLE WINDOW SIGHT GLASS
Double Window Type Sight Glass (Sight Flow Indicator) in Cast Construction & Fabricated design to meet an industrial requirement of various applications to Window type sight flow indicators can be supplied with flapper or transparent/opaque liquid.inspect the process fluid. In Double Window Sight Glass (Sight Flow Indicator) Contains Two Toughened Glasses Mounted opposite to each other. Double Window Type Sight Glass (Sight Flow Indicator) available with various thickness and diameter of glass to suit various applications respects to fluid pressure and temperature. Double Window Type Sight Glass (Sight Flow Indicator) is very easy to replace glass without dismantling the whole Sight Glass assembly from process line.
Technical Specifications
Design Temperature |
: |
Up to 200°C depending upon the type |
Design Pressure |
: |
Up to 20 Kg/cm² depending upon the type |
Line Size |
: |
Up to 400 NB depending upon the type |
Material of wetted parts |
: |
CI/ASTMA216GrWCB/ASTMA351CF8/ASTMA351CF8M/MS/CS/SS304/SS304L/SS316 L and PP/HDPE/PVDF/PFA/PTFELined |
Connection |
: |
Flanged to ASA/ABS/DIN/JIS/Screwed BSP/NPT/Butt Weld |
Send Queries
ELECTROMAGNETIC FLOWMETER
Electromagnetic flow meter is ideal for conductive liquids such as Raw Water, Chilled water, effluents, Potable water etc. Using time proven electromagnetic flow metering principle, the meter achieves a flow meter for pipes from 15mm to 600mm. Since there are no moving parts, the flow meter gives years of maintenance free service. Flow-head can be supplied in Teflon lining or Hard Rubber lining is available with all the features required in a field mounted
Technical Specifications
Media |
Liquids (Clear) |
Viscosity |
200 cp max |
Line Size |
15 NB to 300 NB |
Excitation |
Pulsed DC coil |
Excitation |
Pulsed DC coil |
Display |
Graphical LCD (128x64) |
Transmitter Output |
4 to 20 mA DC, Optically Isolated |
Relay Output & Rating |
Potentials Free Contacts & 5 Amp / 230 VAC |
Linearity |
+/- 0.5% |
Accuracy |
+/- 0.5% F.S. |
Repeatability |
+/- 1% |
Process Temperature |
150 degC max |
Process Pressure |
10 kg/cm2 max |
Lining |
Neoprene / Rubber / PTFE (Teflon) |
Flange |
MS/SS304/SS316 |
Electrode |
SS316/Hastalloy C/Titanium/Monel |
Power Supply |
24 V DC, External |
Power Consumption |
<10 VA |
Response Time |
< 100 m Sec |
Isolation |
1.4 KV between Input, Output & Power Supply |
Temperature Coefficient |
+/- 0.1% per DegC |
Transmitter Enclosure |
Flame-proof, IP-65, IIA, IIB CMRI certified |
Dimensions |
As per chart on rear |
Process Connections |
ASA B 16.5, Flanged |
Mounting |
In-Line (Horizontal OR Vertical) |
Operating Conditions |
Temperature 0 to 55 C / Humidity 5 to 95% non condensing |
Send Queries
OVAL GEAR FLOWMETER
We manufacture a wide range of today's most advanced digital gas flow meters. Each gas flow meter meets exacting standards and can be customized to meet your flow gas meter application requirements (often free of charge). For easy system automation, we offer a full suite of digital communications solutions for our mass flow meters and controllers
Y-STRAINER
Y strainers are a cost-effective solution for the mechanical removal of unwanted solids from liquid, gas or steam lines by means of a perforated or wire mesh straining element. They are used in pipelines to protect pumps, meters, control valves, steam traps, regulators and other process equipment.
Technical Specifications
Body |
: | C.I. / WCB / CF8 / CF8M |
Screen |
: | Brass / SS 304 / 316 |
Ends |
: | Scr / SW / Flanged End |
Hyd. Test Pressure |
: |
WCB / S.S. (Flanged End) Body : 854 Psig (60 Kg/cm²) S.S. (Screwed End) Body : 425 Psig (30 Kg/cm²) C.I. ( Flanged / Screwed) Body : 213 Psig (15 Kg/cm²) |
Size | : | 15 MM to 600 MM |
Send Queries
THERMAL MASS FLOWMETER
Electromagnetic flow meter is ideal for conductive liquids such as Raw Water, Chilled water, effluents, Potable water etc. Using time proven electromagnetic flow metering principle, the meter achieves a flow meter for pipes from 15mm to 600mm. Since there are no moving parts, the flow meter gives years of maintenance free service. Flow-head can be supplied in Teflon lining or Hard Rubber lining is available with all the features required in a field mounted
Technical Specifications
Media |
Liquids (Clear) |
Viscosity |
200 cp max |
Line Size |
15 NB to 300 NB |
Excitation |
Pulsed DC coil |
Excitation |
Pulsed DC coil |
Display |
Graphical LCD (128x64) |
Transmitter Output |
4 to 20 mA DC, Optically Isolated |
Relay Output & Rating |
Potentials Free Contacts & 5 Amp / 230 VAC |
Linearity |
+/- 0.5% |
Accuracy |
+/- 0.5% F.S. |
Repeatability |
+/- 1% |
Process Temperature |
150 degC max |
Process Pressure |
10 kg/cm2 max |
Lining |
Neoprene / Rubber / PTFE (Teflon) |
Flange |
MS/SS304/SS316 |
Electrode |
SS316/Hastalloy C/Titanium/Monel |
Power Supply |
24 V DC, External |
Power Consumption |
<10 VA |
Response Time |
< 100 m Sec |
Isolation |
1.4 KV between Input, Output & Power Supply |
Temperature Coefficient |
+/- 0.1% per DegC |
Transmitter Enclosure |
Flame-proof, IP-65, IIA, IIB CMRI certified |
Dimensions |
As per chart on rear |
Process Connections |
ASA B 16.5, Flanged |
Mounting |
In-Line (Horizontal OR Vertical) |
Operating Conditions |
Temperature 0 to 55 C / Humidity 5 to 95% non condensing |
Send Queries
MECHANICAL FUEL METER
Worldclass Mechanical Fuel Meter, extremely compact, yet easy to read. Robust Aluminum Die Construction. 3 Port Design which allows the meter to be fitted In–Line or with the Inlet & outlet ports at Right Angle. Nutating Disc Mechanism offers high tolerance to fuel contamination .For use with Electric Fuel Pumps or gravity flow (with a minimum gravity head of 4'). Register cap can be easily removed & rotated to every 90° orientation for display. Easy user re calibration. Works with both Fuels & Oils
Technical Specifications
Flow Range | : | 19-76 LPM |
Precision | : | ±0.5% |
Single Count | : | 999L |
Total Count | : | 99999999 L |
Working Temperature | : | -10 to 50 C |
Max Pressure | : | 3.5 Bar |
Inlet/Outlet | : | 1"BSPT |
Waight | : | 1.5KG |
METAL TUBE ROTAMETER
Metal Tube Rotameter is basically a variable area flowmeter. The diffrential pressure across the annulus area is constant and the Flowrate is measured as a function of the position of annulus area created by float position. The position of the float is sensed by a magnet and indicated On the dial in terms of flow rate.
Technical Specifications
Media |
Liquids / Gas (Clear) |
Viscosity |
250 cp max |
Line Size |
15 NB to 100 NB |
Density |
Upto 2.95 |
Flow rate display |
6 Digit LED / LCD |
Transmitter Output |
2-Wire, 4 to 20 mA DC |
Totalizer Display |
6 Digit LED / LCD |
Relay Output & Rating |
Potentials Free Contacts & 5 Amp / 230 VAC |
Linearity |
+/- 0.5% |
Accuracy |
+/- 2% F.S. |
Repeatability |
+/- 1% |
Flange |
MS/SS304/SS316 |
Process Pressure |
60 kg/cm2 max |
Process Temperature |
250 degC max |
Power Supply |
24 V DC, External |
Power Consumption |
<2 VA |
Response Time |
< 100 m Sec |
Output Type |
Loop Powered |
Transmitter Enclosure |
Flame-proof, IP-65, IIA, IIB CMRI certified |
Process Connections |
150 NB ASA Flanged |
Mounting |
In-Line (Horizontal OR Vertical) |
Operating Conditions |
Temperature 0 to 250 degC / Humidity 5 to 95% non condensing |
Send Queries
ORIFICE FLANGE ASSEMBLY
Orifice Flange assembly is a primary flow element consisting of a tab handled square edged orifice plate and optional carrier. The orifice plate is designed and manufactured to meet the requirements in all respects and is suitable for the measurement of the rate of flow most liquids, gases and steam
Technical Specifications
Design : |
Conforms to ISA RP 3.2 , DIN 1952 , BS 1042, ISO 5167, ASME MFC - 3M |
Types : |
Square edge concentric, Quadrant edged, Conical entrance, Eccentric, Segmental. |
Plate Material : |
AISI SS 316 as standard. SS304, SS316L, Hastelloy-C , Monel , PP , PVC , PTFE coated , etc. can be given on request. |
Flange Type : |
Weld neck, Slip on, Threaded, Socket welded with RF or RTJ facing Orifice flanges are in accordance with ASME B16.36 with minimum flange rating of 300# or male - female flanges in accordance with B16.5. |
Flange Material : |
ASTM A 105 as standard, ASTM A182 F11, ASME ASTM A 350, ASTM A182 F316, ASTM A182 F304, ASTM A 182 F 316L, ASTM A 182 F 304L, FRVE etc. |
Pressure Tappings : |
Corner tappings are recommended for sizes upto 1½"; Flange taps from 2" to 16" ; D - D/2 taps for higher sizes. |
Read More
DP TRANSMITTER WITH ORIFICE FLANGE ASSEMBLY
Orifice meter is type of variable head meter. In this meter the obstruction to the flow consist of an engineering constriction in the metered fluid which causes a reduction in the flow pressure. An orifice meter is a conduit and a restriction to create a pressure drop. It uses the same principle as a Venturi nozzle, namely Bernoulli's principle which states that there is a relationship between the pressure of the fluid and the velocity of the fluid. When the velocity increases, the pressure decreases and vice versa
Read MoreTURBINE FLOWMETER
Turbine Flow Meters are useful for liquids & gases in general industrial application. They provide excellent performance with quality & reliability. Suitable for as hygienic application. The flowing media engages a vaned rotor causing it to rotate at an angular velocity proportional to flow rate. The pick -of coil senses the spinning motion of the rotor inside the pipe & converts it into a pulsating electrical signal. Summation of the pulsating electrical signal is directly related to the total flow.
TURBINE FLOWMETER
Media |
Liquids / Gas (Clear) |
Viscosity |
20 cp max |
Line Size |
15 NB to 300 NB |
Density |
Upto 2.95 |
Flow rate display |
4 Digit LED |
Transmitter Output |
4 to 20 mA DC, Optically Isolated |
Totalizer Display |
8 Digit LED |
Relay Output & Rating |
Potentials Free Contacts & 5 Amp / 230 VAC |
Linearity |
+/- 0.5% |
Accuracy |
+/- 1% F.S. |
Repeatability |
+/- 1% |
Flange |
MS/SS304/SS316 |
Process Pressure |
40 kg/cm2 max |
Process Temperature |
150 degC max |
Power Supply |
24 V DC, External |
Power Consumption |
<10 VA |
Response Time |
< 50 m Sec |
Isolation |
1.4 KV between Input, Output & Power Supply |
Transmitter Enclosure |
Flame-proof, IP-65, IIA, IIB CMRI certified |
Process Connections |
150 NB ASA Flanged |
Mounting |
In-Line (Horizontal OR Vertical) |
Operating Conditions |
Temperature 0 to 55 C / Humidity 5 to 95% non condensing |
Read More
VORTEX FLOWMETER
vortex flow meter combines with a unique and powerful combination of digital technology that includes spectral signal processing (SSP).Vortex flow meter is accurate and stable, even in harsh process conditions, and has a highly reliable and robust design that delivers improvements in plant efficiency and reduced operating costs
VORTEX FLOWMETER
Nominal diameter |
: |
DN15-DN300 |
Rated pressure |
: |
PN16, PN25, PN40 |
Body Material |
: |
SUS304 |
Detection Probe |
: |
316L |
Power Supply |
: |
24VDC/220VAC |
Output signal |
: |
4-20 mA, pulse |
Communication Port |
: |
RS485(Modbus), Low & High Flow Alarm |
Gas flow rate |
: |
2 m/s-56m/s |
Linearity |
: |
<1.0% |
Repeatability |
: |
0.33% |
Display |
: |
flow rate, total amount, frequency with nonlinear correction function |
Flow units |
: |
m3/h,kg/h,t/h with density compensation |
Temperature range |
: |
280°C |
Read More
WATER METER
Rotary piston type water meters are very accurate in small sizes and widely used in 1/2" (15mm) to 2" (50mm) sizes for residential uses. Rotary piston type water meters use water to push a piston. The piston rotation speed is in relation to the velocity of water flow. Rotary piston type water meters generally have an internal strainer element that can protect the pistons from getting clogged.
Read More